Difference between revisions of "Ablated endometrium"

From Libre Pathology
Jump to navigation Jump to search
(more)
Line 6: Line 6:
*Alternative to hysterectomy.
*Alternative to hysterectomy.
*Thermal injury - delivered via balloon.
*Thermal injury - delivered via balloon.
*High prevalence of [[endometriosis]] in individuals with hysterectomy post-ablation procedure.<ref name=pmid24398189>{{Cite journal  | last1 = Riley | first1 = KA. | last2 = Davies | first2 = MF. | last3 = Harkins | first3 = GJ. | title = Characteristics of patients undergoing hysterectomy for failed endometrial ablation. | journal = JSLS | volume = 17 | issue = 4 | pages = 503-7 | month =  | year =  | doi = 10.4293/108680813X13693422520602 | PMID = 24398189 }}</ref>


Notes:
Notes:
*''NovaSure'' is commonly used ablation system.<ref>{{Cite journal  | last1 = Gimpelson | first1 = RJ. | title = Ten-year literature review of global endometrial ablation with the NovaSure® device. | journal = Int J Womens Health | volume = 6 | issue =  | pages = 269-280 | month =  | year = 2014 | doi = 10.2147/IJWH.S56364 | PMID = 24648771 }}
*''NovaSure'' is commonly used ablation system.<ref name=pmid24648771>{{Cite journal  | last1 = Gimpelson | first1 = RJ. | title = Ten-year literature review of global endometrial ablation with the NovaSure® device. | journal = Int J Womens Health | volume = 6 | issue =  | pages = 269-280 | month =  | year = 2014 | doi = 10.2147/IJWH.S56364 | PMID = 24648771 }}</ref>
</ref>


==Microscopic==
==Microscopic==

Revision as of 02:23, 22 April 2014

Ablated endometrium, also endometrium post-ablation procedure, is endometrium that has been destroyed to render it nonfunctional.

Endometrial ablation is done to treat menorrhagia and metromenorrhagia in women that are done with their childbearing.

General

  • Alternative to hysterectomy.
  • Thermal injury - delivered via balloon.
  • High prevalence of endometriosis in individuals with hysterectomy post-ablation procedure.[1]

Notes:

  • NovaSure is commonly used ablation system.[2]

Microscopic

Features:

  • Endometrium completely or partially replaced by:
    • Hyaline material, fibrosis.

Images

Sign out

UTERUS, UTERINE CERVIX, TOTAL HYSTERECTOMY:
- SUPERFICIAL FIBROSIS AND HYALINE CHANGE OF THE UTERINE LINING -- COMPATIBLE
  WITH PRIOR ABLATION.
- UTERUS WITH LEIOMYOMAS.
- UTERINE CERVIX WITHIN NORMAL LIMITS.

See also

References

  1. Riley, KA.; Davies, MF.; Harkins, GJ.. "Characteristics of patients undergoing hysterectomy for failed endometrial ablation.". JSLS 17 (4): 503-7. doi:10.4293/108680813X13693422520602. PMID 24398189.
  2. Gimpelson, RJ. (2014). "Ten-year literature review of global endometrial ablation with the NovaSure® device.". Int J Womens Health 6: 269-280. doi:10.2147/IJWH.S56364. PMID 24648771.